Translate

Headline

Josh’s various types of Pumps

Search This Blog

Choosing Right Pump

Wednesday, 5 November 2014

HIPOWER HRNG-430 T6 345 kW Natural Gas Generator Set






Condition New Category Generators Sub Category Natural Gas Generators Engine Package Manufacturer : HIPOWER Engine Manufacturer : PSI HD Engine Model : D219L Manufacture Date : 2014 HP : 612 Hp Governor : Electronic governor Starter : Electric starter Engine RPM: 1800 Cooling Method : Radiator Generator Generator Manufacturer : Stamford Generator Model : HCI434E Leads: 12 Enclosure : Sound Attenuated Enclosure Voltage :480V Power Factor: 0.8 345 kW Prime 431 kVA Generator RPM: 1800 3 Phase 60 Hz Additional Information : WPP Item #: 102401 Battery Battery Charger Hours : Unknown Length : 156 Inches Width : 83 Inches Height : 100 Inches Weight : 10854 lb (4923 kg) approx. DSE8610 Control Panel Newage Alternator Model HCI434E dBA 77 Sound Attenuated Enclosure Mastertrak Telematics Solution (1 Yr. Free Subscription on PSI-HD) Distribution Panel w. 3x50 Amp Twist Lock plus 2 x GFi Duplex and Camlok Device Battery Disconnect Switch Engine Block Heater Racor Crankcase Ventilation Filter Heavy Duty Skid 6A Battery Charger 12/24V, UL Listed Kenko Oil Level Make Up with 5 Gallon Oil Tank Auto Withdrawal LP (dual fuel) MPS (Multiple Parallel System) Electronic Governor Dry Fuel Strainer (Included in Auto LP Liquid Withdrawal Kit) Compression Ratio 10.5:1 Propane Capable 1-Year Factory Warranty Included EPA Emissions Compliant CSA Certified Breaker : 1600A.


Link_












Centrifugal and Rotary Pumps: Fundamentals With Applications




Centrifugal and Rotary Pumps offers both professionals and students a concise reference detailing the design, performance, and principles of operation of the different pumps types defined by the Hydraulic Institute. From historical background to the latest trends and technological developments, the author focuses on information with real-world practicality and techniques you can implement immediately.

Beginning with the fundamentals, the text then shifts to real field cases that address applications, pumpage, system interaction, reliability, failure analysis, and practical solutions. By including specification parameters and criteria for the application of various pumps, this comprehensive book provides necessary and timely material that plant engineers, maintenance staff, operators can use and share with colleagues.


Link_













Tsurumi NK2-2/L Heavy Duty Submersible Dewatering Pump, 3 HP




The NK2-22/L is a general dewatering pump. The NK-series is a KTV-based single-phase dewatering pump. The side-flow, top-discharge design assures efficient motor cooling even when it operates with it's motor exposing in air. Semi-vortex pump design is adopted for maximum durability and maintaining pump’s performance. The pump has a built-in starting capacitor.

  • 3-inch discharge.
  • 3 horse power.
  • 220 voltage.
  • 13 amps.
  • 32-foot cable length.


Link_ 












Saturday, 11 October 2014

Modelling and design of gear pumps with modified tooth profile




This book fills in the gap in publications on the modelling and design of external gear pumps with modified tooth profile. It is dedicated to designers, technologists and researchers, but also to students who want to broaden their knowledge of hydraulic drives and controls. The book is a synthesis of the knowledge about the structure of pumps and technology of manufacturing gears. Special attention is devoted to an original tooth root relief and modifications at the tooth tip. This novel solution opens up prospects for noise emission reduction, trapped volume relief and reduction dynamic loads in gear intermeshing. The knowledge was used to design and build original pumping units. The book’s merits are enhanced by numerous drawings and the accessible way in which the theoretical knowledge is presented.


AUTHOR IN DETAIL

Piotr Osinski, PhD, eng., is the head of the Hydraulic Drives and Vibroacoustics Laboratory at the Faculty of Mechanical Engineering, Wroclaw University of Technology. For over 15 years he has been conducting research focused mainly on gear pumps. He has developed tens of engineering and technological designs.



Link_ 












Vickers V Series Double Vane Pump, 2500 psi Maximum Pressure, 11.8 cubic-inch/rev Displacement, Right Hand Shaft Rotation, 4" CD 61 Flange Inlet, 1-1/2" CD 61 Flange and 1-1/4" CD 61 Flange Outlet, 45 Degrees CW from Inlet


Pumps use mechanical action to move liquids, gases, or slurries (solids suspended in a liquid or gas). The mechanical action is categorized as either positive displacement (PD) or kinetic. PD pumps capture and release discrete amounts of flow into a chamber and then force it out. Some examples of PD pumps are fuel and oil pumps in cars, pumps in hydraulic systems, and bicycle pumps. Kinetic pumps move liquids, gases, or slurries by transferring energy from the pump's movement to the flow. They use an impeller to draw the flow in, add energy to the flow, and move it through a volute (a spiral funnel through which the flow moves), and into the system.  Some examples of kinetic pumps include centrifugal (the most common pump in industrial applications), in-line pumps, sump pumps, and suction pumps. Energy sources for all types of pumps include wind power, manual operation, electricity, and gasoline or diesel fuel.
Vickers is a brand of Eaton, which manufactures electrical, hydraulic, and mechanical power equipment. The company, founded in 1911, and is headquartered in Dublin, Ireland.
  • Fixed-displacement hydraulic pump for a variety of mobile and industrial applications.
  • Independent intra-vane cartridge design allows servicing without removing pump from its mounting.
  • Low-noise design for indoor applications.
  • Right-hand rotation of drive shaft.
  • Maximum pressure rating of 2,500 psi.


Link_